C-01.4 主要技术条件 Technical Conditions
依据标准 standard |
依CNS-90941982、IEC-289等之规定设计、制造及试验 Design, manufacture and test in line with CNS-9094-1982,IEC-289 |
设置场所 location |
屋内用,使用地区情况为海拔2000公尺以下 Indoor only, with altitude of 2000 meters below |
环境温度 temperature |
最高45°C ,平均周温在24小时内不得超过35°C之场所使用 The maximum temperature is 45degrees. The average temperature within 24hours shall not be higher than 35 degrees |
温度等级 rank of temp |
clase H(180°C),连续额定电流4 35%, Class H(180), with the continuous rated current 135%, 线圈温升不超过20°C (电阻法)the maximum temperature of the coil shall not be higher than 120degrees(Resistance Method) |
绝缘耐压 insulation |
0.23KV-0.6KV, AC 4000V/1 分钟 0.23KV-0.6KV.AC4000V/1 min |
容量容许误差 capacity error |
0-+10% |
最大容许电流 max. Permissible current |
5th谐波电流含量35%以下,合成电流120%以下 5th harmonic current content shall be less than 35%, compound current shall be less than 120% |
噪音 noise |
不大于35-40dB No more than 35-40dB |
温度保护 thermal protection |
微动开关(常闭)Micros wtich (closed) |
电抗率 reactance rate |
5.4%, 5.67%, 6%, 7%, 13%, 13.7%, 14%, 14.8% 等 ett |
频率 frequency |
50Hz/60Hz |
电抗器线性度 linear of reactor |
1.8倍额定电流下,L>0.97 Under 1.8 times of the rated current, L>0.97 |
C-01.5 FLOW电抗器的特点Features
|
FLOW滤波电抗器 |
其它厂家电抗器 |
冷压接工艺 |
电抗器与线圈的引出端,采用冷压接工艺连接,减少局部放电,能使场强更加的均匀,连接更可靠。 |
大部分厂家采都热焊接工艺,焊接过容易损伤绝缘材料,造成产品不稳定。 |
0.05的叠装精度 |
FLOW电抗器采用高精度自动设备加工硅钢片,尺寸偏差小于 0.O5MM,硅钢片在叠装时能保证高度的一致性。 |
因自动设备加工硅钢片的成本高,大部分厂家都用剪板机开料,无法保证精度。 |
多个气隙芯柱 |
FLOW电抗器的铁芯采用低损耗冷轧取向硅钢片,芯柱采用多气隙 结构,以保证FLOW的电抗器高达97%的线性度。 |
因多气隙结构工艺复习,成本高,大部分厂家都 用双气隙结构。 |
高线性度 |
电抗器超流运行,在额定电流的4.8倍下,电感值都能保持在0.97% 以上,以免铁心磁饱和。 |
大部分厂家生产的电抗器,线性度只能在1.5— 1.6倍下才能保持在0.95% o |
claseH(180°C) |
电抗器采用H(4 80°C)级材料制造,确保电抗器有良好的耐温能力。 |
大部分厂家采用130°C的绝缘材料制造。 |
H级真空浸漆 |
电抗器采用整体真空浸漆处理,确保低噪音运行,且长时间保持稳定安全运行。 |
因真空浸漆处理的工艺复习,成本高,大部分厂家采用扫漆处理。 |
超低损耗 |
电抗器固件采用无磁性金属材料,铁心采用低损优质材料生产,确保有高的抗谐波能力。 |
为了节省成本,电抗器的固件采用塑料等材料组成,机械强度不足,长时间运行不可靠。 |
内置微动开关 |
每个电抗器都带特殊温度保护开关,能在滤波系统超负荷时,保护系统的安全运行。 |
并不是每个厂家的电抗器都有温度保护开关。 |